preloader
Reachin Chamber
Reachin Chamber

Reachin Chamber

The PAC series of temperature and humidity chambers offers a great choice for conducting cycle testing, including low and high temperatures and humidity. The top-notch construction and dependability of these chambers guarantee that they will pass the stringent testing procedures of several international standards, including ASTM, IEC, MIL, DIN, and more.

The PAC series of temperature and humidity chambers offers a great choice for conducting cycle testing, including low and high temperatures and humidity. The top-notch construction and dependability of these chambers guarantee that they will pass the stringent testing procedures of several international standards, including ASTM, IEC, MIL, DIN, and more.


CME offers testing services to assess the impact of temperature and humidity on your products' properties, functionality, and lifespan. These tests are reproducible, certified, and conducted under accelerated conditions.


Designed by CME's global R&D team, the chambers incorporate the latest simulation technology to provide customers with an exceptional testing experience. The touchscreen controller (Envicom Graphite Series) used in these chambers is highly responsive and includes features such as Chamber Analytics, On-demand cooling, on-screen diagnostics, and safety alarms. Additionally, it is equipped with networking ports like Ethernet, RS 232, RS 485, and a 2GB SD card for storing test data. The chambers can also integrate with third-party software such as NI/LabVIEW.


A significant advantage of CME Reachin Chamber is its high level of customization flexibility. While every test follows procedures outlined by standards such as ASTM, IEC, MIL, and others, there are instances where standard chambers may not be adequate. Recognizing this industry need, our engineers offer extensive customization options, including design modifications, high-performance ramp rates, and integration with other applications like chambers with UTM integration and chambers with Vibration Integration.

Got Technical Question!

Models   PAC 120 PAC 225 PAC 380 PAC 540 PAC 1000 PAC 1500
  A B A B A B A B A B A B
Test Space                          
Dimension
(WXDXH)
mm 500 x 400 x 600 500 x 400 x 600 500 x 600 x 750 500 x 600 x 750 600 x 740 x 840 600 x 740 x 840 750 x 800 x 900 750 x 800 x 900 1000 x 1000 x 1000 1000 x 1000 x 1000 1000 x 1500 x 1000 1000 x 1500 x 1000
inch 20 X 16 X 24 20 X 16 X 24 20 x 24 x 30 20 x 24 x 30 24 x 29 x 33 24 x 29 x 33 30 x 32 x 35 30 x 32 x 35 39 x 39 x 39 39 x 39 x 39 39 x 59 x 39 39 x 59 x 39
Test Space Volume  Ltr / Cuft 120 / 4.2 225 / 8 380 / 13.4 540 / 19 1000 / 35 1500 / 53
Temperature Range  (°C)
(°F)
 - 40 to +180
 -40 to +356
 - 70 to +180
 -94 to +356
 - 40 to +180
 -40 to +356
 - 70 to +180
 -94 to +356
 - 40 to +180
 -40 to +356
 - 70 to +180
 -94 to +356
 - 40 to +180
 -40 to +356
 - 70 to +180
 -94 to +356
 - 40 to +180
 -40 to +356
 - 70 to +180
 -94 to +356
 - 40 to +180
 -40 to +356
 - 70 to +180
 -94 to +356
Ramp rate**  (°C/min) 3/5/6/7/8/10/12/15/20 as per IEC 60068-3-5
**Customized ramp rates are also available                      

Ethernet

Ethernet capability to remotely monitor and control the chamber.

reachin chamber ethernet cmenvirosystems

USB

USB Type-A host port to connect a keyboard or mouse or download CSV data via pen drive [max 2GB] USB Type-B data port for connection to PC for software upgrade and access memory card storage

reachin chamber usb cmenvirosystems

Web Server

Built-in web server allows remote view or control from any internet connected PC, tablet or smart phone

reachin chamber web server cmenvirosystems

NI Lab view

The communication which used is MODBUS RTU protocol, which is an international standard for communication in process instrumentation and automation. Necessary changes to be made in the user’s software to communicate this in MODBUS RTU universal protocol. This feature can be used manual mode only.

reachin chamber ni lab view cmenvirosystems

Hardware

Enhanced with modular controller integrating multi-zone PID control and data acquisition. SIMATIC programmable logic controller. Touch screen controller, PLC and other controller components are of a generic make with an OEM software. Free software upgrades up to one year.

reachin chamber hardware cmenvirosystems

Memory

SD card of 2GB memory will store all the test program data and also the diagnostic data. This card is accessible by USB and Ethernet.

reachin chamber memory cmenvirosystems

Digital Events

1 digital output for switching test specimen via potential free contacts, load max. 24 VDC, 5A

reachin chamber digital events cmenvirosystems

Programs

99 independent programs can be stored with name and number. Each of these programs have segments which can be looped to a previous segment and repeated up to 999 cycles, creating almost unlimited number of segments The chamber can be operated in manual mode, where the set point can directly be changed in the home screen The ramp rate can be set as a value in °C/min or ramp time Graphical representation of the temperature program The time is logged only when the set valve is within the band.

reachin chamber programs cmenvirosystems

Trend Graph

Real time trend graph for temperature set value, temperature process value, humidity set value and humidity process value. Options of zoom in/out, pan and individual plot selection

reachin chamber trend graph cmenvirosystems

Security

Multi level security of guest, user, admin and factory level users with individual password protection All settings can be reset to factory defaults using admin login

reachin chamber security cmenvirosystems

PID

6 zone based PID’s with auto recall of PID based on type of program, segment and zone can be set. Each of these PID’s can be set by using the auto tune feature or manually based on user’s requirements.

reachin chamber pid cmenvirosystems

Process Mimic

Graphical representation of the working of the chamber, with live status of all the components, including the current temperature/humidity process values, compressor suction/discharge pressures and return gas temperature

reachin chamber process mimic cmenvirosystems

Power Resumption Modes

In case of a power failure, option of conditional restart based on temperature/time or continuous

reachin chamber power resumption modes cmenvirosystems

Diagnostics

Event viewer will display a log of all errors/actions with a date and time stamp PLC inputs and outputs status will be indicated

reachin chamber diagnostics cmenvirosystems

Service Monitor

Log of critical components life cycle with a predefined life cycle time and elapsed time in hours

reachin chamber service monitor cmenvirosystems

Delay Start

Real time clock based, delayed start function

reachin chamber delay start cmenvirosystems

Related Products

CME is a leading engineering company specialised in environmental simulation testing technology.